USB dataLogging DUAL Thermo-Hygrometer, Traceable® memory loc

Supplier: VWR Collection
The VWR® Traceable® memory loc USB datalogging DUAL hygrometer monitors temperature and humidity readings in the laboratory with both internal and external sensors. This device can be used in 21 CFR 11 environments.

  • Memory capacity of 688 086 observations
  • Data can never be overwritten or cleared on device
  • Four calibration poins (25 °C and 50% RH for both internal and external sensors)
  • Temperature range: 0 to 65˚C (internal sensor), −20 to 70˚C (external sensor)
  • Humidity range: 0 to 95% non-condensing (internal and external sensor)
  • LCD displays current temperature and humidity conditions, along with the minimum and maximum readings for each parameter
  • Monitors temperature and humidity readings with user-adjstable logging intervals from one minute to twelve hours
  • Status indicators: Low battery indication, memory usage in percentage (rounded to 0,1%), days left until memory is full under current logging interval, USB LCD symbol indicates data downloading status, flashing LCD symbols and audio alarms

Hi/Lo alarms and time/date stamps: Unique alarm settings can be programmed for both parameters – humidity and temperature. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred, as well as when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts, and flashing LCD segments. Data for up to 30 different alarm events can be retrieved with the most current event viewable on the display.

Smart alarm signals out-of-range conditions: When an out-of-range condition is sensed for either temperature or humidity, the smart alarm triggers. Smart alarm features visual and audible indicators which signal continuously until acknowledged, even if the parameter returns to the non-alarm range.

USB data transferring: This datalogging hygrometer allows recorded data, in a CSV format, to be transferred from the thermometer to PC/Mac with a USB flash drive (not included). Specific software is not needed for this thermometer and data can be deleted from memory. Each device has a unique ID that allows multiple units to be used in the same location.

Datalogging features: Monitor readings overnight, on weekends, or for any time period with rolling data log. User-defined datalogging interval of one observation/minute to one observation/12hours. Memory capacity maintains approximately a year of recorded data when using 1 minute intervals and longer when using larger intervals.

Note: Please note that the * indicates the value for temperature and ** the value for humidity

Certifications: Multi-point calibration on an individually-numbered Traceable® Certificate which assures accuracy from an ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It indicates traceability of measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement.
Delivery information: Supplied with stainless steel probe(s), stand, VELCRO®, magnetic strips, wall mount, universal AC adaptor, Traceable® certificate, and batteries.



Log in to see your contract pricing and availability.
  Remember me on this device
 

ORDER

Expand All / Collapse All
Description Accuracy Resolution Weight Pk VWR Catalog Number Quantity
USB dataLogging DUAL Hygrometer, Traceable® memory loc with ambiant sensor (internal and external) ±0,4 °C *
± 3 % (5−75%); ±5%**
0,1 °C *
0,1% **
141,75 1 620-2631
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

WRITE A REVIEW

Need help?

  • Whatever you have to say, positive or negative, is important to us.
  • Providing feedback takes only seconds.
  • Your feedback will be made available to the public on the web.

VWR.com will publish your name as vwr.com user.
You can use this name, or edit and save a nickname.
We recommend authors use their first and last initial.

Please confirm the industry you work in

Example: Pharmaceutical

Please confirm your role

Example: Clinical Trial Assistant

Please confirm your location

Example: New York, NY

REVIEWS (0)

Total Ratings: 0
Avg. Ratings: 0.0 out of 5

Sort all by:

Enter Details

Select the article for which you are looking for Certificate

Indicate the Lot Number. This field is mandatory. Enter 'x' if unknown for VWR Chemicals

Enter Certificate Details

Select Product:

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected. To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty