Centrifuges, benchtop, ventilated/refrigerated, Heraeus® Megafuge® 8 / 8R

Supplier: Thermo Scientific
Heraeus® Megafuge®
These durable centrifuges are available as ventilated or refrigerated versions and provide exceptional capacity in a compact design with a smart, simple interface.

  • Quiet performance provides a safe, stress-free environment
  • One touch operation with pre-saved protocols and password protection
  • Highly visible backlit display for easy reading of parameters
  • Secure, push-button Auto-Lock™ function enables quick and easy rotor exchange and clear chamber access for cleaning convenience
  • Biocontainment sealing options, including certified ClickSeal® lids for glove-friendly, one handed operation
  • 8R model: Powerful refrigeration system with pre-cooling function

The wide variety of the 11 (for Megafuge® 8) or even 13 (for Megafuge® 8R) available rotors provide the flexibility to support both clinical and research applications. These centrifuges conform to latest clinical and safety standards (IVD).

Ordering information: The units are supplied without rotor. Rotors, adapters and other accessories are available separately. Please contact your local VWR sales office for further information.



 

ORDER

Expand All / Collapse All

Megafuge® 8
Description Pk VWR Catalog Number Quantity
Benchtop centrifuge Megafuge® 8, without accessories 1 521-1765
Benchtop centrifuge Megafuge® 8, High Capacity Cell Culture pack, incl. swinging bucket rotor TX-150 (max. 4500 min-1/3260 ×g), 4 round buckets, 4 ClickSeal® bucket lids and adapters for 8× 15 and 4× 50 ml conical tubes per rotor 1 521-1890UK
Benchtop centrifuge Megafuge® 8, High Capacity and Micro pack, incl. swinging bucket rotor TX-150, four buckets for 50 ml conical tubes (unsealed, no adapter needed), and MicroClick 30×2 rotor 1 521-1892
Benchtop centrifuge Megafuge® 8, High Capacity Clinical pack, incl. swinging bucket rotor TX-150, round buckets (set of 4), 4 ClickSeal® bucket lids, blood collection tube adapters 24×5/7 ml (set of 4), and adapter for 14 ml urine tube or 12 ml/10 ml blood collection tube or 15 ml Corex™/Kimble™ tube (set of 4) 1 521-2059
Benchtop centrifuge Megafuge® 8, Middle Capacity Clinical pack, incl. clinical swinging bucket rotor TX-100 with carriers, and adapters 16×5/7 ml 1 521-2248
Benchtop centrifuge Megafuge® 8, Middle Capacity Clinical pack (sealed), incl. clinical swinging bucket rotor TX-100 with sealed carriers, and adapters 8×5/7 ml (set of 4) 1 521-2249
Benchtop centrifuge Megafuge® 8, Microplate pack, incl. swinging bucket rotor M10 (max. 4400 min-1/2576 ×g) and unsealed buckets (set of 2) for max. 4 standard or 2 DW microplates per rotor 1 521-2062
Benchtop centrifuge Megafuge® 8, Clinical pack, incl. clinical swinging bucket rotor TX-100S with sealed carriers, adapters for 1×5/7 ml BD vacutainer/haemagard tubes (set of 8) and adapters for 1×13,5 ml urine tubes (set of 8) 1 521-2255
Benchtop centrifuge Megafuge® 8, Clinical pack, incl. centrifuge, clinical swinging bucket rotor TX-100S with carriers, adapters for 1×5/7 ml BD vacutainer/haemagard tubes (set of 16) and adapters for 1×13,5 ml urine tubes (set of 16) 1 521-2256
Benchtop centrifuge Megafuge® 8, Sterilin™ pack, incl. swinging bucket rotor TX-150, 145 ml round buckets (set of 4) with ClickSeal® biocontainment lids, adapters for 4×13 ml Sterilin primary urine tubes (set of 4) and adapters for 1×30 ml Sterilin universal containers (set of 4) 1 521-2250
Benchtop centrifuge Megafuge® 8, molecular biology pack, incl. swinging bucket rotor TX-150, 4 round buckets with ClickSeal® biocontainment lid, adapters for 4×50 ml conical tubes, adapters for 8×15 ml conical tubes, and MicroClick 24 x 2 rotor 1 521-2261

Megafuge® 8R
Description Pk VWR Catalog Number Quantity
Benchtop refrigerated centrifuge Megafuge® 8R, without accessories 1 521-1857
Benchtop centrifuge Megafuge® 8R, High Performance Clinical Pack, incl. swinging bucket rotor TX-150, 4 round buckets with ClickSeal® biocontainment lids, adapters for 5/7 ml blood collection tubes (set of 4) and adapters for 10 ml blood collection or 5 ml Corex™/ Kimble™ tubes (set of 4) 1 521-2060
Benchtop centrifuge Megafuge® 8R, Cell Culture pack, incl. swinging bucket rotor TX-150 (max. 4500 min-1/3260 ×g), 4 round buckets, 4 ClickSeal® bucket lids and adapters for 8× 15 and 4× 50 ml conical tubes per rotor 1 521-2061UK
Benchtop centrifuge Megafuge® 8R, Microplate pack, incl. swinging bucket rotor M10 (max. 4400 min-1/2576 ×g) and unsealed buckets (set of 2) for max. 4 standard or 2 DW microplates per rotor 1 521-2063
Benchtop refrigerated centrifuge Megafuge® 8R, Molecular Biology pack, incl. TX-150 swinging bucket rotor TX-150, 4 buckets with ClickSeal® biocontainment lids, adapters for 4×50 ml conical tubes and adapters for 8×15 ml conical tubes, and MicroClick 24 x 2 rotor 1 521-2262

Versatile swing-bucket rotors
Description Pk VWR Catalog Number Quantity
Swing out rotor, TX-150, for 24× 5/7 ml blood collection tubes or 8 × 50 ml conical tubes (4500 min-1 / 3260 ×g) 1 521-1778
Swing out rotor, MT-12, for 12 microtubes and filtration columns (13000 min-1 / 16438 ×g) 1 521-1777
Swing out rotor, M-10, for 4 standard microplates or 2 Deepwell microplates (4500 min-1 / 2576 ×g) 1 521-1783
Round buckets for swing out rotor TX-150 4 521-1779
Replacement O-rings for swing out rotor TX-150 2 521-1790
Conical buckets, for swing out rotor TX-150 4 521-1780
ClickSeal® biocontainment lids for glove-friendly, one-handed operation, for swing out rotor TX-150 4 521-1784
Sealed buckets for swing out rotor M-10, R max 109 mm 2 521-1852
Unsealed buckets for swing out rotor M-10 2 521-1789
ClickSeal® biocontainment caps for microplate buckets, for swing out rotor M-10 2 521-1853
Adapter for 1×100 ml round bottom tube (Ø×L: 45×117 mm) 4 521-1792
Adapter, 1×50 ml conical or skirted tube (Ø×L: 29,5×120 mm) 4 521-1793
Adapter, 2×15 ml conical tubes (Ø×L: 17×122 mm) 4 521-1794
Adapter, 4×14 ml urine tubes (Ø×L: 18×124 mm) 4 521-2206
Adapter, 7× 3 / 5 ml blood collection tubes (Ø×L: 12×124 mm) 4 521-1797
Adapter, 6× 5 / 7 ml blood collection tubes (Ø×L: 13×116 mm) 4 521-1796
Adapter, 10× 1,5 / 2 ml microtubes (Ø×L: 11×65 mm) 4 521-1798
Adapter, 1×25 ml universal flat/skirted tube (Ø×L: 25×199 mm) 4 521-1799
Adapter for 50 ml conical buckets, 8×15 ml conical tube (Ø×L: 17×123 mm) 2 521-1817

Clinical swing-bucket rotors
Description Pk VWR Catalog Number Quantity
Swing out clinical rotor, TX-100, incl. unsealed carriers, for 16× 5 / 7 ml blood collection tubes (4500 min-1 / 3260 ×g) 1 521-1782
Swing out clinical rotor, TX-100S, incl. sealed carriers, for 8× 5 / 7 ml blood collection tubes (4500 min-1 / 3215 ×g) 1 521-1781
Adapter for 13,5 ml urine tube (Ø×L: 16×82 mm) 1 521-3246

Swing-bucket rotor packages
Description Pk VWR Catalog Number Quantity
Cell culture package, incl. swing out rotor TX-150, round buckets, adapters for 50 ml conical tubes 1 521-1766
High capacity cell culture package, incl. swing out rotor TX-150, conical buckets, adapters for 15 ml conical tubes 1 521-1767
Clinical rotor package, incl. swing out rotor TX-150, round buckets, ClickSeal® biocontainment lids, adapters for blood collection tubes (5/7 ml and 10 ml) 1 521-1768

Fixed angle rotors
Description Pk VWR Catalog Number Quantity
Fixed-angle rotor, MicroClick, incl. certified biocontainment lid, for 24×2 ml microtubes (16000 min-1 / 24372 ×g for Megafuge® 8; 17850 min-1 /  30279 ×g for Megafuge® 8R) 1 521-1786
Fixed-angle rotor, MicroClick, incl. certified biocontainment lid, for 30×2 ml microtubes or filtration columns (14000 min-1 / 21693 ×g) 1 521-1787
Fixed-angle rotor, MicroClick, incl. certified biocontainment lid, for 18×5 ml microtubes (14000 min-1/ 22351 ×g), for use with Megafuge® 8R only 1 521-1855
Fixed-angle rotor, HIGHConic™ III, with transparent biocontainment lid, for 6×50 ml conical tubes (8700 min-1 / 10155 ×g for Megafuge® 8; 9500 min-1 / 12108 ×g for Megafuge® 8R) 1 521-1785
Fixed-angle rotor, individually sealed, 25°, R max 143 mm, 8×50 ml tubes (30×121 mm), 5600 min-1, 5014 ×g, for use with Megafuge® 8R only 1 521-1567
CLINIConic™ fixed-angle rotor, 37°, R max 140 mm, 30×15 ml tubes (5650 min-1, 4997 ×g) 1 521-1565
Fixed-angle rotor, PCR Strip, for 8×8 PCR strips (14800 min-1 / 16800 ×g) 1 521-1788
Haematocrit fixed-angle rotor, for 24 blood capillaries (13300 min-1 / 17860 ×g) 1 521-1791
Replacement biocontainment lid for fixed angle microtube rotor MicroClick 24×2 1 521-1861
Replacement O-rings for fixed angle microtube rotor MicroClick 24×2 1 KIT 521-1939
Replacement biocontainment lid for fixed angle microtube rotor MicroClick 30 × 2 and PCR strip rotor 8×8 1 521-1863
Replacement O-rings for fixed angle microtube rotor MicroClick 30×2 and PCR strip rotor 8×8 1 521-1862
Replacement biocontainment lid for fixed angle rotor HIGHConic III 1 521-1864
Replacement O-rings for fixed angle rotor HIGHConic III 1 HERA75003058
Capillary sealing kit for Hematocrit fixed angle rotor 1 521-0706
Replacement capillaries for Hematocrit fixed angle rotor 100 521-1880
Replacement linear scale for Hematocrit fixed angle rotor 1 521-1023
Adapter for MicroClick rotors 30×2 and 24×2; 0,2 ml PCR tube (Ø×L: 6,5×20 mm) 30 521-1800
Adapter for MicroClick rotors 30×2 and 24×2; 0,25 ml microtube (Ø×L: 6×46 mm) 30 521-1816
Adapter for MicroClick rotors 30×2 and 24×2; 0,5 ml microtube (Ø×L: 8×44 mm) 30 521-1815
Adapter for Microclick 18×5 rotor, 1,5/2 ml micro tube (Ø×L: 11×45 mm) 2 521-1854
Adapter for HIGHConic III rotor, 1,5 / 2 ml microtube (Ø×L: 11×40 mm) 2 HERA75005807
Adapter for HIGHConic III and individually sealed rotor, 3,5 ml round bottom tube (Ø×L: 11×100 mm) 2 HERA75005806
Adapter for HIGHConic III and individually sealed rotor, 12 ml round bottom tube (Ø×L: 16×95 mm) 2 HERA75005804
Adapter for HIGHConic III rotor, 16 ml round bottom tube (Ø×L: 18×123 mm) 2 HERA75005803
Adapter for HIGHConic III rotor, for 1× 38 ml round bottom tube (Nalgene Oak Ridge tube) 2 HERA75005802
Adapter for CliniConic rotor, 37°, 10 ml round bottom tube 1 521-1860
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

SPECIFICATIONS

Model Megafuge® 8 Megafuge® 8R
Max. capacity - fixed angle rotor 6×50 ml (with HIGHConic™ rotor)
Max. capacity - swing-out rotor 4×145 ml (with TX-150 rotor)
Max. speed - fixed angle rotor (min-1) 16000 (with MicroClick 24×2 rotor) 17850 (with MicroClick 24 x 2 rotor)
Max. speed - swing-out rotor (min-1) 4500 (with TX-150 rotor)
Max. RCF - fixed angle rotor (×g) 24328 (with MicroClick 24×2 rotor) 30279 (with MicroClick 24 x 2 rotor)
Max. RCF - swing-out rotor (×g) 3260 (with TX-150 rotor)
Temperature (°C) - −10...+40 °C
Acceleration/braking ramps 2
Control Microprocessor
Programs 4 protocols via direct access key 3 protocols via direct access key, plus 96 additional programs accessible via folder
Timer 99 h 59 min + continuous
Anti-unbalance system SMARTSpin
Languages English, French, German, Spanish, Italian, Dutch and Russian
Noise level (dB(A)) <58 (with TX-150 rotor); <61 (with MicroClick 24×2 rotor) <56 (with all rotors); <52 (with MicroClick 24×2 rotor)
Power supply 230 V / 50 - 60 Hz
Power consumption (W) 310 750
W×D×H (mm) 370×480×310 (lid closed) 460×670×320 (lid closed)
Weight (kg) 35 71

WRITE A REVIEW

Need help?

  • Whatever you have to say, positive or negative, is important to us.
  • Providing feedback takes only seconds.
  • Your feedback will be made available to the public on the web.

VWR.com will publish your name as vwr.com user.
You can use this name, or edit and save a nickname.
We recommend authors use their first and last initial.

Please confirm the industry you work in

Example: Pharmaceutical

Please confirm your role

Example: Clinical Trial Assistant

Please confirm your location

Example: New York, NY

REVIEWS (0)

Total Ratings: 0
Avg. Ratings: 0.0 out of 5

Sort all by:

Enter Details

Select the article for which you are looking for Certificate

Indicate the Lot Number. This field is mandatory. Enter 'x' if unknown for VWR Chemicals

Enter Certificate Details

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected. To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty
 

Terms & Conditions

These terms and conditions cover all sales of products and services by VWR International Ltd (VWR) in the United Kingdom and any information and advice given whether charged for or not. No variation in these terms and conditions will apply unless agreed by VWR in writing. Orders are accepted only on the condition that no conditions of purchase shall apply. 

Prices/Charges

VWR has the right to change the prices shown in catalogues and price lists at any time and to invoice at prices current at the date of receipt of an order.

‘Price on application’ (POA) quotations and all other quotations will be valid for 30 days from the date of the quotation, unless otherwise notified by VWR.

All prices in catalogues and quotations are net of Value Added Tax and any other taxes or duties. These will be charged separately, if applicable. VWR reserve the right to apply a freight charge on all deliveries. 

Payment

Unless otherwise agreed in writing payment in full is due within 30 days from date of invoice. VWR has the right to charge interest on all overdue sums at the rate of five percent per annum over the base lending rate of the Bank of England calculated at the date of actual payment.

  • Customers who exceed their credit limits will be asked to pay in advance for additional products until the account is settled. 
  • Delivered products will remain the property of VWR until paid for.
  • VWR has the right to deliver an order in instalments, and the customer is required to pay the invoice for each instalment within 30 days from date of invoice. 
  • Any claims for shortages must be made within 7 days of a delivery.  
  • Any claims for non-ordered items or non delivery must be made within 7 days of receiving the invoice. 
Products

The products we supply are intended for use in accordance with the documentation and manufacturer specifications under the user’s sole responsibility. 

Products supplied by VWR cannot be used as active pharmaceutical ingredients (APIs) in human or veterinary medicine because, as a distributor, VWR does not fulfil the requirements laid down in the guidelines for GMP medicinal products for human and veterinary use.

Customers using  products from VWR  in a pharmaceutical, cosmetic, food, pesticide or any other regulated application must carry out their own internal checks and controls to ensure that the items are of an appropriate quality/ grade and in compliance with their local laws and regulations (e.g. European Pharmacopoeia) etc.   Please contact VWR if you have any questions about your intended use and if the product you wish to purchase is suitable for that purpose. In no event shall VWR INTERNATIONAL be liable if a customer uses a product that does not fit with the intended application. 

It is the customer's responsibility to comply with all applicable health, safety and other regulations and to take appropriate steps in relation to the storage, handling, sale and use of the products.

Return of Damaged or Unsuitable Goods

No goods may be returned to VWR without the authorisation of VWR.

Authorisation to return products damaged during delivery must be requested within 3 days of delivery. VWR has the right to repair and return damaged products.

Authorisation for the return of products which fail to meet current published manufacturers specifications must be requested in writing within 28 days of delivery. VWR will assist customers, at customers’ expense, to obtain any manufacturer’s warranty consistent with that granted to VWR.

Authorisation for the return of products, other than those damaged during delivery, delivered in error or those that do not meet specification, must be requested within 10 days of delivery. Credit (less a handling charge of 15% of the invoice value of all products returned subject to a minimum charge of £30) will be given for those products authorised for return which are unused and in re-saleable condition other than those in the categories shown:

  • open chemicals or diagnostics
  • refrigerated or other perishables
  • items with an expired shelf life or an expiration date too short for resale
  • any article that has been delivered direct by a third party supplier
  • discontinued items
  • items not purchased from VWR.

Authorisation will be subject to the condition that the products are returned to VWR Customer Service Centre or to the manufacturer or other source notified by VWR, by registered post if permitted, (for which VWR will supply a label) or via the VWR scheduled van service, for which a handling charge will be made for each line.

Articles that have been delivered on our behalf by a third party supplier will not be accepted back at the VWR Customer Service Centre.

Health, Safety and Liability

Risk in products will pass at the time of delivery to the customer.

The customer is responsible for unloading and transporting large and/or heavy items from delivery vans.

In view of the hazards of certain chemicals and apparatus the customer must ensure that the products purchased are in a safe condition and that a safe system of work is in place taking into account all available information. None of the products sold are intended for human consumption unless otherwise clearly stated.

In view of the wide range of uses of chemicals and apparatus, the customer will be solely responsible for determining the suitability and specification of products, services, information and advice for its purposes. VWR has the right, without notice, to supply product of different specifications, sources, and pack size to that published or ordered. The customer is required to ensure that that the use of any products supplied by VWR do not infringe third party intellectual property rights.

In view of the above, liability of VWR for any loss or damage suffered by a customer and arising by reason of defects in the products or otherwise howsoever is limited to the invoice price of the products in respect of or in relation to which loss or damage is claimed. Any liability accepted by VWR under these terms and conditions is in lieu of any warranty or condition implied by law as to the quality or fitness for any particular purpose of the products and save as provided in these terms and conditions VWR will not be under any liability, whether in contract, tort, breach of statutory duty or otherwise in respect of defects in products delivered or for any injury (other than death or personal injury caused by VWR negligence as defined in the Unfair Contract Terms Act 1977) damage or loss resulting from such defects or from any information, service or advice provided by VWR or its employees, contractors or agents. In no event shall VWR be liable for any consequential loss whether or not resulting from force majeure. The customer indemnifies VWR against any claims from its employees, contractors or agents.

Print These Terms